Aquadopp Profiler 2.0 - 2 MHz

Small and compact, short-range current profiling; option for PUV wave measurements

  • Up to 10 m current profiling range
  • Optional right-angle head for measurements close to boundaries or in shallow water
  • Pressure-based (PUV) directional wave measurements

Overview

The Aquadopp Profiler is a highly versatile Acoustic Doppler Current Profiler (ADCP) available in three profiling range options, from < 1 m to > 85 m. The 2 MHz version has a current profiling range of up to 10 m. Designed for simple yet powerful operation, this current profiler is packed with features used by engineers and researchers to enable accurate and effective hydrodynamic data collection in a variety of environmental conditions.

The upgraded Aquadopp Profiler design offers improved noise immunity as well as 6% broadband measurements and “hibernation mode” between measurements, enabling precise data collection with lower power consumption. Increased internal battery storage extends potential deployment time.

  • Currents
  • Waves

Highlights

  • Up to 10 m current profiling range
  • Optional right-angle head for measurements close to boundaries or in shallow water
  • Pressure-based (PUV) directional wave measurements
  • LED blinks when pinging for peace of mind during deployment

Usage

  • Near-bed current profiles with fine vertical resolution
  • Mean flow measurements with a focus on ease of use and simplicity
  • Measurements in areas with strong variations in flow speeds
  • Projects with needs for both high-resolution and normal-range current measurements with optional HR
  • Measurements of waves and currents from a single instrument
  • Studies of tidal currents

Setup

The 2MHz Aquadopp Profiler, designed for current measurements in shallow water (offering a 10m profiling range), is set up using the Nortek deployment software, enabling users to customize measurement schemes and assess power requirements.

Deployment

Compact size and an optional right-angle head allow for very near-bed deployments, maximizing water column coverage in shallow areas. Teams of all sizes can deploy an Aquadopp Profiler successfully.

Data

Nortek postprocessing software and/or display software is available for review, visualization, and processing of data, after deployment or in real time.

Download PDF

Nominal profiling range

10 m

Cell size

0.1-2 m

Maximum number of cells

200

Minimum blanking

0.2 m

Velocity range (along beam)

±1 m/s, ±2.5 m/s, ±5 m/s

Velocity range (horizontal)

±2.3 m/s, ±5.75 m/s, ±11.5 m/s

Accuracy

±1% of measured value ±0.5 cm/s

Horizontal velocity precision (consult instrument SW)

Typ. 1 cm/s

Maximum sampling rate (output)

1 Hz

Wave measurements

PUV (optional)

Sampling

Same as velocity

Resolution

0.5 dB

Dynamic range

90 dB

Transducer acoustic frequency

2 MHz

Number of beams

3

Beam width

0.85° (1.7° total)

Maximum profiling range

4.0 m

Cell size

0.01-0.13 m

Minimum blanking

0.1 m

Maximum number of cells

256

Velocity range

3 cm/s - 0.65 m/s

Range velocity limitations

Product of profiling range and velocity should not exceed 0.12 m2/s

Accuracy

±1% of measured value ±0.5 cm/s

Max. sampling rate

8 Hz

Temperature:

Temp. range

-4 to +40 °C

Temp. accuracy/resolution

0.1 °C/0.01 °C

Temp. time response

<1 min

Compass:

Solid state magnetometer

Accuracy/resolution

<2° for tilt < 30° /0.01°

Tilt:

Solid state accelerometer

Accuracy/resolution

0.2° for tilt <30° / 0.01°

Maximum tilt

Full 3D

Up or Down

Automatic detect

Pressure:

Piezoresistive

Range

30 m / 100 m / 500 m

Accuracy/precision

0.5% FS / 0.005% of full scale

Capacity

16 GB

Accuracy

±1 min/year

Backup in absence of power

4 weeks

I/O

RS-422 (inquire for RS-232)

Communication baud rate

9600 Baud - 1.2 Mbaud (default 115200 Baud)

User control

Nortek Deployment Software or direct ASCII commands, with binary or ASCII data output

Operating system

Agnostic

Functions

Deployment planning, instrument configuration, data retrieval and conversion. Online data display

DC input

9-24 VDC

Absolute maximum DC input

26 VDC

Maximum peak current

4.5 A

Power consumption

Consult Nortek Deployment Software

Sleep current

< 10 uA

Transmit power

Adjustable

Internal battery capacity

1-3 x 50 Wh (Alkaline); 2-3 x 165 Wh (Lithium), 1-3 x 76 Wh (Li-Ion)

Battery weight

430g per 50 Wh (Alkaline); 380g per 165 Wh (Lithium); 300g per 76 Wh (Li-ion)

Operating temperature

-5 to +40 °C

Storage temperature

-20 to +60 °C

Shock and vibration

Shock: IEC 60068-2-27, Vibration: IEC 60068-2-64

EMC

EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019

Depth rating

500 m

Bulkhead (Impulse)

MCBH-8-FS Brass

Cable

PMCIL-8-MP on 5 m (default) polyurethane cable

Standard model

POM, Naval Brass, Titanium Gr. 5, Epoxy

Maximum housing diameter

75 mm

Maximum length

S2VP: 589 mm; S2SP: 634 mm

Weight in air (without batteries)

S2VP: 2500g; S2SP: 2710g

Weight in water (without batteries)

S2VP: -120g; S2SP: -50g

S2VP

Shallow water, 2MHz, Vertical orientation, Profiler

S2SP

Shallow water, 2MHz, Side-looking orientation, Profiler

Aquadopp Profiler 2MHz - S2VP
Aquadopp Profiler 2MHz - S2SP

Declaration of conformity

Technical specifications for Aquadopp Profiler 2MHz delivered pre-2024

Aquadopp Profiler 2MHz

2 MHz Standard head

2 MHz Right-angle head

Pressure sensor, 0-30 m

Pressure sensor, 0-100 m

Pressure sensor, 0-500m

5m RS422 polyurethane cable with 8-pin inline connector and USB converter

10m RS422 polyurethane cable with 8-pin inline connector and USB converter

New features, fixes and functionality

Note. Firmware for legacy systems (pre April 2008) with version numbers starting with 0. or 1.

New features, fixes and functionality

Deployment planning, execution and recovery

Deployment planning, execution and recovery

Note. Firmware for legacy systems (pre April 2008) with version numbers starting with 0. or 1.

New features, fixes and functionality

Display of profiler data. Can be used in combination with Prof2NDP

The standard deployment software for Nortek Aquadopp and Aquadopp Profiler instruments purchased after October 2023.

The software can be launched from your web browser, installed from Microsoft Store or downloaded as an offline installer file.

Data conversion

Processing of waves

Data processing and ready-to-print reporting software. Request quote for license

Wave and current profile data visualization and processing software for online applications. Request quote for license

Analysis and processing of currents and directional waves. Request quote for license

Analysis and processing of current profiles. Request quote for license

Request a quote

Found the right product? Fill out the form to request a quote.

Cart

Total $0.00
Next

In the final step you can choose to pay by card or generate a quote PDF.