Aquadopp Profiler Z-Cell 2

1 MHz

Jusqu'à 25 m de mesure de profil de courant et sans zone blanche. Permet de mesurer proche du fond ou en proche surface

Aperçu

Need to collect accurate 3D currents very near the seabed or sea surface, in addition to a full water-column profile?

The Z-Cell (Zero Cell) Aquadopp allows current measurement to start right at the instrument’s level through an innovative approach: it has side-looking beams fully integrated into the instrument’s head, effectively removing the blanking distance normally applicable to ADCPs.

  • Currents
  • Waves

Points forts

  • Up to 25 m current profiling range
  • Capable of measuring surface or bottom currents
  • PUV-based directional wave measurements

Utilisation

  • Mounted on bottom frames, with ability to measure also near-bed currents
  • Mean flow measurements with high focus on ease of use and simplicity
  • Measurements in flow regimes with strong variations in flow speeds
  • Projects with needs for both high-resolution and normal-range current measurements
  • Studies of tidal currents
  • Measurements of combinations of waves and currents
  • Mounted on surface buoys, with the ability to measure also surface currents

Setup

The 1MHz Aquadopp Z-Cell, designed for current measurements up to a 25m range, is set up using the Nortek deployment software, enabling users to customize measurement schemes and assess power requirements. The Z-cell functionality allows measurements at the level of the instrument head, eliminating the “blanking distance” at which most ADCPs cannot measure.

Deployment

Teams of all sizes can deploy an Aquadopp Z-Cell successfully thanks to its compact size. The instrument is optimal for deployments near boundaries such as the seabed or sea surface.

Data

Nortek postprocessing software and/or display software is available for review, visualization and processing of data, after deployment or in real time. The instrument can provide data from the level of the instrument as well as a full water column profile.

Télécharger le PDF

Water velocity measurements

Nominal profiling range

25 m

Cell size

0.25-4 m

Maximum number of cells

200

Minimum blanking

0 m with Z-cell enabled

Velocity range (along beam)

±1 m/s, ±2.5 m/s, ±5 m/s

Velocity range (horizontal)

±2.3 m/s, ±5.75 m/s, ±11.5 m/s

Accuracy

±1% of measured value ±0.5 cm/s

Horizontal Velocity precision**

Typ. 1cm/s

Maximum sampling rate (output)

1 Hz

Wave measurements

PUV (optional)

  • Depending on scattering conditions

** Consult instrument SW

Echo intensity

Sampling

Same as velocity

Resolution

0.5 dB

Dynamic range

90 dB

Transducer acoustic frequency

1 MHz

Number of beams

3

Beam width

1.7° (3.4° total)

Echo Intensity

Sampling

Same as velocity

Resolution

0.5 dB

Dynamic range

90 dB

Transducer acoustic frequency

1 Mhz

Number of beams

3

Beam width

1.7° (3.4° total)

HR option

Maximum profiling range

8 m

Cell size

0.02-0.25 m

Minimum blanking

0.1 m

Maximum number of cells

256

Velocity range

3 cm/s - 1.3 m/s

Range velocity limitations

Product of profiling range and velocity should not exceed 0.25 m2/s

Accuracy

±1% of measured value ±0.5 cm/s

Max. Sampling rate

4 Hz

Sensors

Temperature:

Temp. range

-4 to +40 °C

Temp. accuracy/resolution

0.1 °C/0.01 °C

Temp. time response

<1 min

Compass:

Solid State Magnetometer

Accuracy/resolution

<2° for tilt <30°/0.01°

Tilt:

Solid State Accelerometer

Accuracy/resolution

0.2° for tilt <30°/0.01°

Maximum tilt

Full 3D

Up or Down

Automatic detect

Pressure:

Piezoresistive

Range

30 m / 100 m / 500 m

Accuracy/precision

0.5% FS / 0.005% of full scale

Data recording

Capacity

16 GB

Real-time clock

Accuracy

±1 min/year

Backup in absence of power

4 weeks

Data communications

I/O

RS-422 (Inquire for RS-232)

Communication baud rate

9600 Baud-1.2 Mbaud (default 115200 Baud)

User control

Nortek Deployment Software or direct ACSII commands, with binary or ASCII data output

Software

Operating system

Agnostic

Functions

Deployment planning, instrument configuration, data retrieval and conversion. Online data display.

Power

DC input

9-24 VDC

Absolute maximum DC input

26 VDC

Maximum peak current

4.5 A

Power consumption

Consult Nortek Deployment Software

Sleep current

< 40 uA

Transmit power

Adjustable

Batteries

Internal Battery capacity

1-3x 50 Wh (Alkaline), 2-3x 165 Wh (Lithium), 1-3x 76Wh (Li-Ion)

Battery weight

430g per 50 Wh (Alkaline), 380g per 165 Wh (Lithium), 300g per 76Wh (Li-Ion)

Environmental

Operating temperature

-5 to +40 °C

Storage temperature

-20 to +60 °C

Shock and vibration

Shock: IEC 60068-2-27, Vibration: IEC 60068-2-64

EMC

EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019

Depth rating

500 m

Connectors

Bulkhead (Impulse)

MCBH-8-FS Brass

Cable

PMCIL-8-MP on 5m (default) polyurethane cable

Materials

Standard model

POM, Naval Brass, Titanium Gr.5, Epoxy

Dimensions (see drawings for details)

Maximum housing diameter

75 mm

Maximum length

602 mm

Weight

Weight in air (without batteries)

2280 g

Weight in water (without batteries)

-400 g (buoyant)

Weight in air, short housing (without batteries)

1680 g

Weight in water, short housing (without batteries)

50 g

Head configurations

S1VZ

Shallow water, 1 Mhz, Vertical orientation, Z-Cell Profiler

Online cable information

Power wire gauge

20AWG; 20AWG; 18AWG

Hardware

Standard; Standard; Long cable kit

Cable length

0-10m; 10-50m; 50-500m

Input voltage

9-24VDC; 24VDC +/-0,5; 48VDC +2/-5

Absolut maximum DC input

26 VDC; 26 VDC; 51 VDC

Communication

RS232/RS422/115200; RS232/RS422/115200; RS422/115200