Nortek DVL 1 M Hz 4000 side2 1
Nortek DVL 1 M Hz 4000 front
IMG 0139
Nortek DVL 1 M Hz 4000 side2 1
Nortek DVL 1 M Hz 4000 front
IMG 0139

Navigation

DVL1000 - 4000 m

Tracking du fond de 0.2 à 75 m. Opérationnel jusqu'à une profondeur de 4000 m

Overview

The DVL1000 is the world’s smallest survey-grade Doppler Velocity Log. It combines compact design with unprecedented functionality, being able to fly higher in the water column and closer to the seabed than similar equipment. It has a maximum operational depth of 4000 m and is ideally suited for subsea navigation where size and weight are a concern. This 1 MHz Doppler Velocity Log is used by
industry leaders in the subsea market because of its high accuracy and state-of-the-art technology.

  • Currents
  • Bottom track

Highlights

  • Industry-wide acceptance
  • Bottom track from 0.2-75 m range
  • Quality estimates - per beam and ping

Usage

  • Observation-class ROVs and AUVs
  • Near-bottom operations
  • Highly accurate subsea surveys
  • Easy integration with high-grade INS

Integration

This 6000m rated survey-grade DVL is equipped for easy integration with leading INS systems to create a robust, reliable navigation system, tested and proven across AUV, ROV, USV and other platforms of all sizes. As with all of Nortek's DVLs, the DVL1000 is compatible with top control software including EIVA, Seebyte and Greensea.

Reliability

Tested in demanding conditions in the Oslo fjord, the DVL1000 has a proven track record in areas of variable bathymetry and conditions. The water track feature provides a velocity backup if the bottom becomes out of range. The spectrum analyzer assures thorough system level integration.

Results

The DVL1000 provides reliable navigation in the most demanding conditions across multiple platforms. The addition of simultaneous current profiles improves operational safety and allows opportunistic oceanographic data collection.

Download PDF

Single ping std @ 3 m/s 0.5 cm/s
Long-term accuracy ±0.1% / ±0.1 cm/s
Minimum altitude 0.2 m
Maximum altitude 75 m
Velocity resolution 0.01 mm/s
Maximum ping rate 8 Hz max

Minimum accuracy 0.3% of measured value ± 0.3 cm/s
Minimum range 2.0 m

Minimum accuracy 0.3% of measured value ± 0.3 cm/s
Velocity resolution 0.1 cm/s
Interval User-specified Nth ping
Maximum range 30 m
Blanking 0.1 m
Cell size 0.2-2.0 m
Max # cells 150

Operating temperature -4 to +40 °C
Storage temperature -20 to +60 °C
Vibration IEC60068-2-64
EMC approval IEC/EN 61000-6-2, 61000-6-3

Depth rating 4000 m
Weight 2.7 kg
Weight in water 1.7 kg
Height 164 mm
Diameter ø114 mm

Frequency of operation 1 MHz
Beam width 2.9° 2.9°
Configuration 4-beam Janus array convex transducer, 25° beam angle
Internal memory 16 GB / 64 GB optional
Frequency of operation 500 kHz
Bandwidth 25% centered at transmit frequency

Serial (either serial or ethernet) Configurable RS232 or RS422, 8-pin male
Ethernet 10/100 Mbits Auto MDI-X.TCP/IP, UDP/IP, HTTP protocols. Fixed IP / DHCP client /Auto IP address assignment. UPnP and Nortek proprietary instrument discovery over Ethernet. IEEE1588/PTP and NTP for absolute time stamping.Multiple simultaneous data format transmission possible.
Data formats Nortek proprietary w/ 1 ms time stamp accuracy, NMEA0183, Variants of PDx
Trigger Internal 1, 2, 3, 4, 5, 6, 7 or 8 Hz or Trigger In. Trigger option through command (Ethernet or serial) External TTL or 485 lines: (configurable Rising/Falling/Edges)

Pressure 0.1% FS /precision better than 0.002% of full scale per sample
Temperature -4° to +40 °C ± 0.1 °C

DC input 12-48 V
Maximum continuous current 1.5 A
Average power 1.3 W*
* Power based on 1 Hz sampling and altitude with greatest transmit pulse.

Standard models POM and titanium housing

DVL 1000 General Arrangement - NGA032-002 Rev.-

End User Declaration - Nortek DVL
Declaration of conformity

DVL1000, 4000m

4 beam head

Titanium housing, 4000m rated

16 GB SD card data logger

64 GB

Pressure sensor 0-10 m, 0,1%

Pressure sensor 0-20 m, 0,1%

Pressure sensor 0-30 m, 0,1%

Pressure sensor 0-50 m, 0,1%

Pressure sensor 0-100 m, 0,1%

Pressure sensor 0-200m, 0,1%

Pressure sensor 0-500m, 0,1%

Pressure sensor 0-1000m, 0,1% (DVL1000, 4000m only)

Pressure sensor 0-4000m, 0,1% (DVL1000, 4000m only)

Cable, 8 pin female ethernet AD2CP with RS485 trigger

Cable, 8 pin female serial AD2CP with RS485 trigger

Cable, 8 pin female ethernet AD2CP with TTL trigger

Cable, 8 pin female serial AD2CP with TTL trigger

Bottom track

Current profiles, 4 beams

Request a quote

Found the right product? Fill out the form to request a quote.

Cart

Total 0,00 $US
Next

In the final step you can choose to pay by card or generate a quote PDF.