Nortek Aquadopp profiler 1 M Hz z cell sidelooking
Z Cell low
Nortek 30269888551
Nortek Aquadopp profiler 1 M Hz z cell sidelooking
Z Cell low
Nortek 30269888551

Ocean currents

Aquadopp Z-Cell 1 MHz

Up to 25 m current profiling range and no blanking; can measure near-surface or near-bottom currents

  • Up to 25 m current profiling range
  • Capable of measuring surface or bottom currents
  • PUV-based directional wave measurements

Visão geral

Need to collect accurate 3D currents very near the seabed or sea surface, in addition to a full water-column profile?

The Z-Cell (Zero Cell) Aquadopp allows current measurement to start right at the instrument’s level through an innovative approach: it has side-looking beams fully integrated into the instrument’s head, effectively removing the blanking distance normally applicable to ADCPs.

  • Currents
  • Waves

Destaques

  • Up to 25 m current profiling range
  • Capable of measuring surface or bottom currents
  • PUV-based directional wave measurements

Uso

  • Mounted on bottom frames, with ability to measure also near-bed currents
  • Mean flow measurements with high focus on ease of use and simplicity
  • Measurements in flow regimes with strong variations in flow speeds
  • Projects with needs for both high-resolution and normal-range current measurements
  • Studies of tidal currents
  • Measurements of combinations of waves and currents
  • Mounted on surface buoys, with the ability to measure also surface currents

Setup

The 1MHz Aquadopp Z-Cell, designed for current measurements up to a 25m range, is set up using the Nortek deployment software, enabling users to customize measurement schemes and assess power requirements. The Z-cell functionality allows measurements at the level of the instrument head, eliminating the “blanking distance” at which most ADCPs cannot measure.

Deployment

Teams of all sizes can deploy an Aquadopp Z-Cell successfully thanks to its compact size. The instrument is optimal for deployments near boundaries such as the seabed or sea surface.

Data

Nortek postprocessing software and/or display software is available for review, visualization and processing of data, after deployment or in real time. The instrument can provide data from the level of the instrument as well as a full water column profile.

Baixar PDF

Water velocity measurements

Maximum profiling range

12-25 m

Cell size

0.3-4 m

Minimum blanking

0.20 m when profiling; 0 m when Z-Cell enabled

Maximum number of cells

96

Measurement cell position

N/A

Default position (along beam)

N/A

Velocity range

±10 m/s

Accuracy

±1% of measured value ±0.5 cm/s

Velocity precision

Consult instrument software

Maximum sampling rate (output)

1 Hz

Internal sampling rate

6 Hz

Echo intensity (along slanted beams)

Sampling

Same as velocity

Resolution

0.45 dB

Dynamic range

90 dB

Transducer acoustic frequency

1 MHz

Number of beams

3

Beam width

3.4°

Echo Intensity

Sampling

Same as velocity

Resolution

0.5 dB

Dynamic range

90 dB

Transducer acoustic frequency

1 Mhz

Number of beams

3

Beam width

1.7° (3.4° total)

HR option (Z-Cell will be disabled)

Maximum profiling range

6 m

Cell size

20-300 mm

Minimum blanking

0.2 m

Maximum number of cells

128

Range/Velocity limitations

Product of profiling range and velocity should not exceed 1.0 m2/s

Accuracy

±1% of measured value ±0.5 cm/s

Max. sampling rate

1 Hz (continuous mode), 8 Hz (burst mode)”

Sensors

Temperature:

Thermistor embedded in head

Temp. range

-4 to +40 °C

Temp. accuracy/resolution

0.1 °C/0.01 °C

Temp. time response

10 min

Compass:

Magnetometer

Accuracy/resolution

2°/0.1° for tilt < 20°

Tilt:

Liquid level

Accuracy/resolution

0.2°/0.1°

Maximum tilt

30°

Up or Down

Automatic detect

Pressure:

Piezoresistive

Range

0-100 m (inquire for options)

Accuracy/precision

0.5% FS / 0.005% of full scale

Data recording

Capacity

9 MB, can add 4/16 GB

Data record

9*Ncells + 32 bytes

Diagnostics record

N/A

Wave record

Nsamples * 24 + 60 bytes

Mode

Stop when full (default) or wrap mode

Real-time clock

Accuracy

±1 min/year

Backup in absence of power

4 weeks

Data communications

I/O

RS-232 or RS-422

Communication baud rate

300-115200 Bd

Recorder download baud rate

600/1200 kBd for both RS-232 and RS-422

User control

Handled via "Aquadopp" software, ActiveX®function calls, or direct commands with binary or ASCII data output

Software

Functions

Deployment planning, instrument configuration, data retrieval and conversion (for Windows®).

Power

DC input

9-15 V DC

Maximum peak current

3 A

Avg. power consumption

0.05 W

Sleep current

< 100 μA

Transmit power

0.3-20 W, 4 adjustable levels

Batteries

Battery capacity

50 Wh (alkaline or Li-ion), 165 Wh (lithium), Single or dual

New battery voltage

13.5 V DC (alkaline)

Environmental

Operating temperature

-5 to +40 °C

Storage temperature

-20 to +60 °C

Shock and vibration

IEC 721-3-7

EMC approval

IEC 61000

Depth rating

300 m

Connectors

Bulkhead

MCBH-8-FS

Cable

PMCIL-8-MP on 10 m polyurethane cable

Materials

Standard model

POM and polyurethane plastics with titanium fasteners

Dimensions

Maximum diameter

75 mm

Maximum length

~550 mm (single battery), +110 mm (double battery) depending on head configuration

Weight

Weight in air

2.2 kg

Weight in water

0.2 kg

Options

1) Alkaline, lithium or Li-ion external batteries, 2) Inquire for different head configurations

Online cable information

Power wire gauge

20AWG; 20AWG; 18AWG

Hardware

Standard; Standard; Long cable kit

Cable length

0-10m; 10-50m; 50-500m

Input voltage

9-24VDC; 24VDC +/-0,5; 48VDC +2/-5

Absolut maximum DC input

26 VDC; 26 VDC; 51 VDC

Communication

RS232/RS422/115200; RS232/RS422/115200; RS422/115200

Request a quote