Maximum profiling range

4-10 m

Cell size

0.1-2 m

Minimum blanking

0.05 m

Maximum number of cells

96

Measurement cell position

N/A

Default position (along beam)

N/A

Velocity range

±10 m/s

Accuracy

±1% of measured value ±0.5 cm/s

Velocity precision

Consult instrument software

Maximum sampling rate(output)

1 Hz

Internal sampling rate

23 Hz

Sampling

Same as velocity

Resolution

0.45 dB

Dynamic range

90 dB

Transducer acoustic frequency

2 MHz

Number of beams

3

Beam width

1.7°

Maximum profiling range

3 m

Cell size

7-150 mm

Minimum blanking

0.03 m

Maximum number of cells

128

Range/Velocity limitations

Product of profiling range and velocity should not exceed 0.5 m2/s (2 MHz system)

Accuracy

±1% of measured value ±0.5 cm/s

Max. sampling rate

1 Hz (continuous mode, )8 Hz (burst mode)”

Temperature:

Thermistor embedded in head

Temp. range

-4 to +40 °C

Temp. accuracy/resolution

0.1 °C/0.01 °C

Temp. time response

10 min

Compass:

Magnetometer

Accuracy/resolution

2°/0.1° for tilt < 20°

Tilt:

Liquid level

Accuracy/resolution

0.2°/0.1°

Maximum tilt

30°

Up or Down

Automatic detect

Pressure:

Piezoresistive

Range

0-100 m (inquire for options)

Accuracy/precision

0.5% FS / 0.005% of full scale

Capacity

9 MB, can add 4/16 GB

Data record

9*Ncells + 32 bytes

Diagnostics record

N/A

Wave record

Nsamples * 24 + 60 bytes

Mode

Stop when full (default) or wrap mode

Accuracy

±1 min/year

Backup in absence of power

4 weeks

I/O

RS-232 or RS-422

Communication baud rate

300-115200 Bd

Recorder download baud rate

600/1200 kBd for both RS-232 and RS-422

User control

Handled via "Aquadopp" software, ActiveX®function calls, or direct commands with binary or ASCII data output

Functions

Deployment planning, instrument configuration, data retrieval and conversion (for Windows®)

DC input

9-15 V DC

Maximum peak current

3 A

Avg. power consumption

0.03 W

Sleep current

< 100 μA

Transmit power

0.3-20 W, 3 adjustable levels

Battery capacity

1) 50 Wh (alkaline or Li-ion), 2) 165 Wh (lithium), 3) Single or dual

New battery voltage

13.5 V DC (alkaline)

Operating temperature

-5 to +40 °C

Storage temperature

-20 to +60 °C

Shock and vibration

IEC 60068-1/IEC60068-2-27/IEC60068-2-64

EMC approval

IEC 61000

Depth rating

300 m, (3000 m and 6000 m option)

Bulkhead

MCBH-8-FS

Cable

PMCIL-8-MP on 10 m polyurethane cable

Standard model

POM and polyurethane plastics with titanium fasteners

Maximum diameter

75 mm

Maximum length

~550 mm (single battery), +110 mm (double battery) depending on head configuration

Weight in air

2.2 kg

Weight in water

0.2 kg

SHP 2MHz General Arrangement - NGA011-016 Rev.-
SVP 2MHz General Arrangement - NGA011-018 Rev.-

Declaration of conformity

The standard deployment software for Nortek Aquadopp and Aquadopp Profiler instruments purchased after October 2023.

The software can be launched from your web browser, installed from Microsoft Store or downloaded as an offline installer file.

Cart

Total $0.00
Next

In the final step you can choose to pay by card or generate a quote PDF.