Nortek Aquadopp current meter 2 M Hz new1
Nortek 30097906539 2
Aquadopp profiler 1
Aquapro S2 VP
Nortek Aquadopp current meter 2 M Hz new1
Nortek 30097906539 2
Aquadopp profiler 1
Aquapro S2 VP

Oceanography

Aquadopp Profiler 2.0 - 2 MHz

Petit et compact, pour les applications nécessitant une portée de mesure courte. Mesure de la houle par PUV en option.

Aperçu

The Aquadopp Profiler is a highly versatile Acoustic Doppler Current Profiler (ADCP) available in four profiling range options, from < 1 m to > 85 m. The 2 MHz version has a current profiling range of up to 10 m. Designed for simple yet powerful operation, this current profiler is packed with features used by engineers and researchers to enable accurate and effective hydrodynamic data collection in a variety of environmental conditions.

  • Currents
  • Waves

Points forts

  • Up to 10 m current profiling range
  • Optional right-angle head
  • PUV-based directional wave measurements

Utilisation

  • Near-bed current profiles with fine vertical resolution
  • Mean flow measurements with high focus on ease of use and simplicity
  • Measurements in flow regimes with strong variations in flow speeds
  • Projects with needs for both high-resolution and normal-range current measurements
  • Measurements of combinations of waves and currents
  • Studies of deep-water currents
  • Studies of tidal currents
  • Mounted on surface buoys
  • Suitable for wave buoys

Setup

The 2MHz Aquadopp Profiler, designed for current measurements in shallow water (offering a 10m profiling range), is set up using the Nortek deployment software, enabling users to customize measurement schemes and assess power requirements.

Deployment

Compact size and an optional right-angle head allow for very near-bed deployments, maximizing water column coverage in shallow areas. Teams of all sizes can deploy an Aquadopp Profiler successfully.

Data

Nortek postprocessing software and/or display software is available for review, visualization, and processing of data, after deployment or in real time.

Télécharger le PDF

Maximum profiling range (depending on scattering conditions)

4-10 m

Cell size

0.1-2 m

Maximum number of cells

200

Minimum blanking

0.2 m

Velocity range (along beam)

±1 m/s, ±2.5 m/s, ±5 m/s

Accuracy

±1% of measured value ±0.5 cm/s

Horizontal velocity precision (consult instrument SW)

Typ. 1cm/s

Maximum sampling rate (output)

2 Hz

Internal sampling rate

4 Hz

Wave measurements

PUV (optional)

Sampling

Same as velocity

Resolution

0.5 dB

Dynamic range

90 dB

Transducer acoustic frequency

2 MHz

Number of beams

3

Beam width

1.7°

Maximum profiling range

4 m

Cell size

0.01-0.13 m

Minimum blanking

0.1 m

Maximum number of cells

200

Range/Velocity limitations

Product of profiling range and velocity should not exceed 0.14 m2/s

Accuracy

±1% of measured value ±0.5 cm/s

Max. sampling rate

8 Hz

Temperature:

Temp. range

-4 to +40 °C

Temp. accuracy/resolution

0.1 °C/0.01 °C

Temp. time response

<1 min

Compass:

Solid State Magnetometer

Accuracy/resolution

<2° for tilt <30°/0.01°

Tilt:

Solid State Accelerometer

Accuracy/resolution

0.2° for tilt <30°/0.01°

Maximum tilt

Full 3D

Up or Down

Automatic detect

Pressure:

Piezoresistive

Range

30m / 100m / 500m

Accuracy/precision

0.25% FS / 0.005% of full scale

Capacity

16 GB

Accuracy

±1 min/year

Backup in absence of power

4 weeks

I/O

RS-422

Communication baud rate

9600 Baud-1.2 Mbaud (default 115200 Baud)

User control

Nortek Deployment Software or direct ASCII commands, with binary or ASCII data output

Operating system

Agnostic

Functions

Deployment planning, instrument configuration, data retrieval and conversion. Online data display.

DC input

9-24 VDC

Absolut maximum DC input

26 VDC

Maximum peak current

4.5 A

Power consumption

Consult Nortek Deployment Software

Sleep current

< 10 uA

Transmit power

0.45-45W, adjustable over 20dB

Battery capacity

1-3x 50 Wh (Alkaline), 1-3x 165 Wh (Lithium), 1-3x 76Wh (Li-Ion)

Battery weight

430g per 50 Wh (Alkaline), 380g per 165 Wh (Lithium), 300g per 76 Wh (Li-Ion)

New battery voltage

13.5 VDC

Operating temperature

-5 to +40 °C

Storage temperature

-20 to +60 °C

Shock and vibration

Shock: IEC 60068-2-27, Vibration: IEC 60068-2-64

EMC

EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019

Depth rating

500m

Bulkhead (impulse)

MCBH-8-FS Brass

Cable

PMCIL-8-MP on 5m (default) polyurethane cable

Standard model

POM, Naval Brass, Titanium Gr. 5, Epoxy

Maximum housing diameter

75 mm

Maximum length

S2VP: 589 mm; S2SP: 634 mm

Weight in air (without batteries)

S2VP: 2500 g; S2SP: 2710 g

Weight in water (without batteries)

S2VP: -120g; S2SP: -50g

S2VP

Shallow water, 2MHz, Vertical orientation, Profiler

S2SP

Shallow water, 2MHz, Side-looking orientation, Profiler

Aquadopp Profiler 2 MHz - S2VP
Aquadopp Profiler 2 MHz - S2SP

Declaration of conformity

Technical specifications for Aquadopp Profiler 2MHz delivered pre-2024

Aquadopp Profiler 2MHz

3000m Aquadopp Profiler 2MHz

6000m Aquadopp Profiler 2MHz

2 MHz Standard head - AQP

2 MHz Right-angle head - ASP

2MHz Deepwater Standard head - A3P

2MHz Deepwater Standard head - A6P

2MHz 3000m Right-angle head 3SP

Pressure sensor, 0-10 m

Pressure sensor, 0-20 m

Pressure sensor, 0-30 m

Pressure sensor, 0-50 m

Pressure sensor, 0-100 m

Pressure sensor, 0-200m

Pressure sensor 0-3000 m (3000m Aquadopp Profiler 2MHz only)

Pressure sensor 0-6000 m (6000m Aquadopp Profiler 2MHz only)

5m RS422 polyurethane cable with 8-pin inline connector and USB converter

10m RS232 polyurethane cable with 8-pin inline connector and USB converter

Request a quote

Found the right product? Fill out the form to request a quote.

Panier

Total 0,00 $US
Suivant

In the final step you can choose to pay by card or generate a quote PDF.