Nortek Aquadopp profiler 1 M Hz Toplooking
Aquadoppprofiler1 Mhz 4
Aquadopp Profiler1 Mhz 3
Nortek Aquadopp profiler 1 M Hz Toplooking
Aquadoppprofiler1 Mhz 4
Aquadopp Profiler1 Mhz 3

Oceanography

Aquadopp Profiler 1 MHz

500 m, Generation 2

Small and compact, with up to 25 m current profiling range; option for PUV wave measurements

  • Up to 25 m current profiling range
  • Optional right-angle head
  • Pressure-based (PUV) directional wave measurements

Overview

The Aquadopp Profiler is a highly versatile Acoustic Doppler Current Profiler (ADCP) available in four profiling range options, from < 1 m to > 85 m. The 1 MHz version has a current profiling range of up to 25 m. Designed for simple yet powerful operation, this current profiler is packed with features used by engineers and researchers to enable accurate and effective hydrodynamic data collection in a variety of environmental conditions.

See the details of the Generation 2 Aquadopp updates in the release notes here.
Download our guide to Aquadopp ADCPs here.
  • Currents
  • Waves

Highlights

  • Up to 25 m current profiling range
  • Optional right-angle head
  • Pressure-based (PUV) directional wave measurements

Usage

  • Mean flow measurements with high focus on ease of use and simplicity
  • Projects with needs for both high-resolution and normal-range current measurements
  • Studies of tidal currents
  • Measurements of combinations of waves and currents
  • This instrument is used to perform river discharge measurements by River Insight.

Setup

The 1MHz Aquadopp Profiler, designed for current measurements up to a 25m range, is set up using the Nortek deployment software, enabling users to customize measurement schemes and assess power requirements.

Deployment

Compact size and an optional right-angle head allow for very near-bed deployments, maximizing water column coverage in shallow areas. Teams of all sizes can deploy an Aquadopp Profiler successfully.

Data

Nortek postprocessing software and/or display software is available for review, visualization, and processing of data, after deployment or in real time.

Download PDF

Water velocity measurements

Nominal profiling range*

25 m

Cell size

0.25-4 m

Maximum number of cells

200

Minimum blanking

0.2 m

Velocity range (along beam)

User-selectable 1.0 to 5.0 m/s

Accuracy

±1% of measured value ±0.5 cm/s

Horizontal Velocity precision**

Typ. 1cm/s

Maximum sampling rate (output)

1 Hz

Wave measurements

PUV (optional)

* Depending on scattering conditions

** Consult instrument SW

Echo intensity

Sampling

Same as velocity

Resolution

0.5 dB

Dynamic range

90 dB

Transducer acoustic frequency

1 MHz

Number of beams

3 (see GA drawings for angles)

Beam width

1.7° (3.4° total)

HR option

Maximum profiling range

8.0 m

Cell size

0.02-0.25 m

Minimum blanking

0.1 m

Maximum number of cells

256

Velocity range

Product of profiling range and velocity should not exceed 0.25 m2/s

Accuracy

±1% of measured value ±0.5 cm/s

Max. sampling rate

4 Hz

Notes

Extended Velocity Range (EVR) option not available.

Sensors

Temperature:

Temp. range

-4 to +40 °C

Temp. accuracy/resolution

0.1 °C/0.01 °C

Temp. time response

<1 min

Compass:

Solid State Magnetometer

Accuracy/resolution

<2° for tilt <30°/0.01°

Tilt:

Solid State Accelerometer

Accuracy/resolution

0.2° for tilt <30°/0.01°

Maximum tilt

Full 3D orientation sensing. Recommended instrument orientation and allowable tilt depend on the measurement application.

Up or Down

Automatic detect

Pressure:

Piezoresistive

Range

30m/100m/500m

Accuracy/precision

0.5% FS / 0.005% of full scale

Data recording

Capacity

16 GB

Real-time clock

Accuracy

±1 min/year

Backup in absence of power

4 weeks

Data communications

I/O

RS-422 (inquire for RS-232)

Communication baud rate

9600 Baud-1.2 Mbaud (default 115200 Baud)

User control

Nortek Deployment Software or direct ASCII commands, with binary or ASCII data output

Software

Operating system

Cross platform

Functions

Deployment planning, instrument configuration, data retrieval and conversion. Online data display.

Power

DC input

9-24 VDC

Absolute maximum DC input

26 VDC

Maximum peak current

4.5 A

Power consumption

Consult Nortek Deployment Software

Sleep current

< 40 uA

Transmit power

Adjustable

Batteries

Internal Battery capacity

1-3x 50 Wh (Alkaline), 2-3x 165 Wh (Lithium), 1-3x 76 Wh (Li-Ion)

Battery weight

430 g per 50 Wh (Alkaline), 380 g per 165 Wh (Lithium), 300 g per 76 Wh (Li-Ion)

Environmental

Operating temperature

-5 to +40 °C

Storage temperature

-20 to +60 °C

Shock and vibration

Shock: IEC 60068-2-27, Vibration: IEC 60068-2-64

EMC

EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019

Depth rating

500 m

Connectors

Bulkhead (Impulse)

MCBH-8-FS Brass

Cable

PMCIL-8-MP on 5 m (default) polyurethane cable

Materials

POM, Naval Brass, Titanium Gr.5, Epoxy

Dimensions (see drawings for details)

Maximum housing diameter

75 mm

Maximum length

S1VP: 591 mm, S1SP: 634 mm

Weight

Weight in air (without batteries)

S1VP: 2500 g, S1SP: 2710 g

Weight in water (without batteries)

S1VP: -120 g, S1SP: -50 g

Weight in air, short housing (without batteries)

S1VP: 1900 g, S1SP: 2110 g

Weight in water, short housing (without batteries)

S1VP: 330 g, S1SP: 400g

Head configurations

S1VP

Shallow water, 1MHz, Vertical orientation, Profiler

S1SP

Shallow water, 1MHz, Side looking, Profiler

Online cable information

Cable length

A) 0-10m, B) 10-50m, C) 50-500m

Power wire gauge

A) 20AWG, B) 20AWG, C) 18AWG

Hardware

A) Standard, B) Standard, C) Long cable kit*

Input voltage

A) 9-24VDC, B) 24VDC +/-0,5, C) 48VDC +2/-5

Absolut maximum DC input

A) 26 VDC, B) 26 VDC, C) 51 VDC

Communication

A) RS232/RS422/115200, B) RS232/RS422/115200, C) RS422/115200

*Start-up voltage: greater than or equal to 26V. Recommended operating range: 43-50 V.

Compare similar products

Nortek Aquadopp profiler 2 1 M Hz
Nortek Signature1000 1 Mhz Sideview 1
Nortek AWAC 2 1 M Hz frontview
Products
Aquadopp Profiler 1 MHz
Signature 1000
AWAC 1 MHz
Frequency
1 MHz
2 Mhz
1 Mhz
Features
Currents, waves
Currents, waves
Currents, waves, turbulence, echosounder, ice
Profiling range
25 m
10 m
25 m (burst), 30 m (average)
Depth rating options
500 m
500 m
300 m, 4000 m
Maximum number of cells
200
200
256 burst, 200 average
Maximum sampling rate
1 Hz
1 Hz
16 Hz
Wave measurment capabilities
Up to 10 m depth, PUV
Up to 10 m depth, PUV
Up to 30 m depth, AST
Additional options
Z-cell option (no blanking distance)
N/a
Burst, waves, ice, echosounder, HR (high-resolution), onboard wave processing

Request a quote

Found the right product? Fill out the form to request a quote.

Cart

Total $0.00
Next

In the final step you can choose to pay by card or generate a quote PDF.